WeldGuard
All joints

J-2960

repairRepair
Line
LN-12
Station
1776+00
Weld date
2026-06-03
Spec
24" × 0.375"

33.60560, -104.00760

No open cross-check alerts on this joint.

Welder passes

  1. RootWorking side
    Ray Delgado RC-501

    Jun 3, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  2. RootDitch side
    Curtis Vann RC-514

    Jun 3, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  3. Hot PassDitch side
    Ray Delgado RC-501

    Jun 3, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  4. Hot PassWorking side
    Curtis Vann RC-514

    Jun 3, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  5. FillWorking side
    Ray Delgado RC-501

    Jun 3, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  6. FillDitch side
    Curtis Vann RC-514

    Jun 3, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  7. CapDitch side
    Ray Delgado RC-501

    Jun 3, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  8. CapWorking side
    Curtis Vann RC-514

    Jun 3, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  9. RepairWorking side
    Ray Delgado RC-501

    Jun 3, 2026, 10:30 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

NDT results

  • RTRepair

    Jun 3, 2026, 8:00 PM · D. Halloran (ASNT II)

    Moisture / weather-related porosity (not charged to welder)

    Not charged to a welder.

    Repairable indication — grind and re-weld authorized.

    RT film map — clock position3 indications
    12123456789101112
    • EUExcess reinforcement12:5312:56 · 0.26" · d 0.01"Within acceptance limits.
    • PORPorosity7:007:11 · 1.12" · d 0.07"POR exceeds API 1104 acceptance limits — charged for re-work.
    • LCLow cap8:228:23 · 0.12" · d 0.04"Call varies by inspectorWithin acceptance limits.

Visual inspection (CWI)

  • Final visualAcceptTravis KellermanJun 3, 2026, 11:40 AM

    API 1104

Coating inspection

No coating inspection recorded for this joint.