J-3447

acceptedAccept
Line
LN-12
Station
2068+20
Weld date
2026-06-08
Spec
24" × 0.375"

33.90267, -104.28032

No open cross-check alerts on this joint.

Welder passes

  1. RootWorking side
    Ray Delgado RC-501

    Jun 8, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  2. RootDitch side
    Curtis Vann RC-514

    Jun 8, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  3. Hot PassDitch side
    Ray Delgado RC-501

    Jun 8, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  4. Hot PassWorking side
    Curtis Vann RC-514

    Jun 8, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  5. FillWorking side
    Ray Delgado RC-501

    Jun 8, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  6. FillDitch side
    Curtis Vann RC-514

    Jun 8, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  7. CapDitch side
    Ray Delgado RC-501

    Jun 8, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  8. CapWorking side
    Curtis Vann RC-514

    Jun 8, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

NDT results

  • RTAccept

    Jun 8, 2026, 8:00 PM · P. Estrada (ASNT II)

    No recordable indications.

    RT film map — clock position2 indications
    12123456789101112
    • EUExcess reinforcement5:475:49 · 0.26" · d 0.03"Minor indication, within acceptance limits.
    • PORPorosity9:449:47 · 0.30" · d 0.01"Minor indication, within acceptance limits.

Visual inspection (CWI)

  • Final visualRepairTravis KellermanJun 8, 2026, 1:36 PM
    • Excess cap reinforcement

    API 1104 · Visual call outside API 1104 acceptance limits - grind and repair.

    Charged to Curtis Vann RC-514

Coating inspection

No coating inspection recorded for this joint.