WeldGuard
All joints

J-3240

repairRepair
Line
LN-12
Station
1944+00
Weld date
2026-06-06
Spec
24" × 0.375"

33.77640, -104.16440

No open cross-check alerts on this joint.

Welder passes

  1. RootDitch side
    Weston Trahan RC-133

    Jun 6, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G

    6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max

  2. RootWorking side
    Weston Trahan RC-133

    Jun 6, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G

    6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max

  3. Hot PassWorking side
    Bo Kinchen RC-146

    Jun 6, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G

    6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max

  4. Hot PassDitch side
    Hector Ruiz RC-528

    Jun 6, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  5. FillDitch side
    Kelly Boudreaux RC-350

    Jun 6, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  6. FillWorking side
    Dale Whitcomb RC-533

    Jun 6, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G

    6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max

  7. CapWorking side
    Kelly Boudreaux RC-350

    Jun 6, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  8. CapDitch side
    Dale Whitcomb RC-533

    Jun 6, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G

    6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max

  9. RepairWorking side
    Dale Whitcomb RC-533

    Jun 6, 2026, 10:30 AM · logged by C. Ramirez (Survey)

    WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G

    6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max

NDT results

  • RTRepair

    Jun 6, 2026, 8:00 PM · D. Halloran (ASNT II)

    Cap pass — incomplete fusion charged to the cap welder

    Charged to Dale Whitcomb (RC-533) — counts as a strike under the 3-repair rule.

    Repairable indication — grind and re-weld authorized.

    RT film map — clock position2 indications
    12123456789101112
    • PORPorosity2:112:17 · 0.54" · d 0.06"Within acceptance limits.
    • SISlag inclusion5:225:39 · 1.77" · d 0.07"SI exceeds API 1104 acceptance limits — charged for re-work.

Visual inspection (CWI)

  • Final visualAcceptJoanne ReyesJun 6, 2026, 9:06 AM

    API 1104

Coating inspection

No coating inspection recorded for this joint.