WeldGuard
All joints

J-0062

acceptedAccept
Line
LN-12
Station
37+20
Weld date
2026-05-04
Spec
24" × 0.375"

31.83782, -102.38472

No open cross-check alerts on this joint.

Welder passes

  1. RootWorking side
    Ray Delgado RC-501

    May 4, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  2. RootDitch side
    Curtis Vann RC-514

    May 4, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  3. Hot PassWorking side
    Curtis Vann RC-514

    May 4, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  4. Hot PassDitch side
    Ray Delgado RC-501

    May 4, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  5. FillDitch side
    Curtis Vann RC-514

    May 4, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  6. FillWorking side
    Ray Delgado RC-501

    May 4, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  7. CapWorking side
    Curtis Vann RC-514

    May 4, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  8. CapDitch side
    Ray Delgado RC-501

    May 4, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

NDT results

  • RTAccept

    May 4, 2026, 8:00 PM · D. Halloran (ASNT II)

    No recordable indications.

    RT film map — clock position2 indications
    12123456789101112
    • EUExcess reinforcement1:341:35 · 0.17" · d 0.04"Minor indication, within acceptance limits.
    • LCLow cap8:118:13 · 0.22" · d 0.06"Call varies by inspectorMinor indication, within acceptance limits.

Visual inspection (CWI)

  • Final visualAcceptHector SalasMay 4, 2026, 1:15 PM

    API 1104

Coating inspection

  • AcceptRenee Alcorta5/4/2026
    DFT
    26 mils
    Holidays
    0
    Surface temp
    93°F
    Humidity
    38%

    SSPC-SP 10 near-white blast · FBE + ARO overlay