WeldGuard
All joints

J-4003

acceptedAccept
Line
LN-12
Station
2401+80
Weld date
2026-06-13
Spec
24" × 0.375"

34.24183, -104.59168

No open cross-check alerts on this joint.

Welder passes

  1. RootDitch side
    Ray Delgado RC-501

    Jun 13, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  2. RootWorking side
    Curtis Vann RC-514

    Jun 13, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  3. Hot PassWorking side
    Ray Delgado RC-501

    Jun 13, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  4. Hot PassDitch side
    Curtis Vann RC-514

    Jun 13, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  5. FillDitch side
    Ray Delgado RC-501

    Jun 13, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  6. FillWorking side
    Curtis Vann RC-514

    Jun 13, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  7. CapWorking side
    Ray Delgado RC-501

    Jun 13, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  8. CapDitch side
    Curtis Vann RC-514

    Jun 13, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

NDT results

  • RTAccept

    Jun 13, 2026, 8:00 PM · P. Estrada (ASNT II)

    No recordable indications.

    RT film map — clock position1 indication
    12123456789101112
    • UCUndercut9:079:12 · 0.49" · d 0.06"Minor indication, within acceptance limits.

Visual inspection (CWI)

  • Final visualAcceptHector SalasJun 13, 2026, 11:12 AM

    API 1104

Coating inspection

No coating inspection recorded for this joint.