J-4381
weldedNot inspected- Line
- LN-12
- Station
- 2628+60
- Weld date
- 2026-06-17
- Spec
- 24" × 0.375"
34.47241, -104.80336
No open cross-check alerts on this joint.
Welder passes
- RootWorking sideWeston Trahan RC-133
Jun 17, 2026, 8:35 AM · logged by C. Ramirez (Survey)
WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G
6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max
- RootDitch sideMarcus Cole RC-118
Jun 17, 2026, 8:35 AM · logged by C. Ramirez (Survey)
WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G
6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max
- Hot PassWorking sideBo Kinchen RC-146
Jun 17, 2026, 9:10 AM · logged by C. Ramirez (Survey)
WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G
6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max
- Hot PassDitch sideTy Maldonado RC-552
Jun 17, 2026, 9:10 AM · logged by C. Ramirez (Survey)
WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4
4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max
- FillWorking sideCody Latham RC-165
Jun 17, 2026, 9:45 AM · logged by C. Ramirez (Survey)
WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G
6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max
- FillDitch sideKelly Boudreaux RC-350
Jun 17, 2026, 9:45 AM · logged by C. Ramirez (Survey)
WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G
6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max
- CapWorking sideSam Whitfield RC-388
Jun 17, 2026, 10:20 AM · logged by C. Ramirez (Survey)
WPS-1104-DH-01 Rev 2SMAW downhill 5G / 6GE6010 / E8010-G
6–36 in OD · wall 0.188–0.75 in · hardness 248 HV10 max
- CapDitch sideKelly Boudreaux RC-350
Jun 17, 2026, 10:20 AM · logged by C. Ramirez (Survey)
WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4
4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max
NDT results
No inspection recorded yet.
Visual inspection (CWI)
- Undercut
API 1104 · Visual call outside API 1104 acceptance limits - grind and repair.
Charged to Jesse Karr RC-455
Call disputedCall overturned8/1/2026Kyle Bassett (Contractor QC) — Undercut call challenged — depth gauged at less than 1/32 in and not continuous. Escalating to Senior CWI.
Escalated to Senior CWI · Alicia Brenner (Senior CWI / SCWI)
Senior CWI re-inspected in the ditch. Undercut 0.020 in, non-continuous — acceptable per API 1104 9.3.9. Charge to welder removed.
Revised call: Repair → Accept
Coating inspection
No coating inspection recorded for this joint.