WeldGuard
All joints

J-3286

acceptedAccept
Line
LN-12
Station
1971+60
Weld date
2026-06-06
Spec
24" × 0.375"

33.80446, -104.19016

No open cross-check alerts on this joint.

Welder passes

  1. RootWorking side
    Ray Delgado RC-501

    Jun 6, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  2. RootDitch side
    Curtis Vann RC-514

    Jun 6, 2026, 8:35 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  3. Hot PassDitch side
    Ray Delgado RC-501

    Jun 6, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  4. Hot PassWorking side
    Curtis Vann RC-514

    Jun 6, 2026, 9:10 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  5. FillWorking side
    Ray Delgado RC-501

    Jun 6, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  6. FillDitch side
    Curtis Vann RC-514

    Jun 6, 2026, 9:45 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  7. CapDitch side
    Ray Delgado RC-501

    Jun 6, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

  8. CapWorking side
    Curtis Vann RC-514

    Jun 6, 2026, 10:20 AM · logged by C. Ramirez (Survey)

    WPS-1104-TI-11 Rev 1SMAW uphill 6G (fixed)E6010 / E7018-H4

    4–36 in OD · wall 0.188–0.75 in · hardness 235 HV10 max

NDT results

  • RTAccept

    Jun 6, 2026, 8:00 PM · D. Halloran (ASNT II)

    No recordable indications.

    RT film map — clock position2 indications
    12123456789101112
    • SISlag inclusion12:571:00 · 0.33" · d 0.09"Minor indication, within acceptance limits.
    • UCUndercut6:516:55 · 0.37" · d 0.09"Minor indication, within acceptance limits.

Visual inspection (CWI)

  • Final visualAcceptHector SalasJun 6, 2026, 1:57 PM

    API 1104

Coating inspection

No coating inspection recorded for this joint.